Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
J Prosthet Dent ; 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38580583

RESUMO

STATEMENT OF PROBLEM: The type of veneer preparation is often chosen according to the patient's tooth structure and occlusion. Taking biomechanics into account in this decision-making process provides the clinician with more technical information on how to improve the clinical longevity of restorations. However, biomechanical analyses of veneer preparation designs are sparse. PURPOSE: The purpose of this 3-dimensional (3D) finite element analysis with microcomputed tomography (µCT) data obtained from realistic models was to assess the influence of different preparations for ceramic and composite resin veneers on restoration and resin layer stress distribution. MATERIAL AND METHODS: Four replicas of a central incisor were printed and prepared for laminate veneers with 4 different incisal edge designs: shoulder (SH), palatal chamfer (PC), palatal chamfer and oblique fracture involving the distal angle (OF-PC), and palatal chamfer involving horizontal incisal fracture (IF-PC). After fabrication and cementation of the veneers, the restored replicas were assessed with µCT, and 3D finite element models were built. A 100-N load was applied on the palatal surface at 60 and 125 degrees relative to the longitudinal axis. Maximum principal stress and stress distribution on the veneers, cement layer, and tooth structure were calculated and analyzed. RESULTS: The SH preparation exhibited better stress distribution than the PC preparation, and the cement layer and the veneer were subjected to lower stress. The IF-PC preparation had better stress distribution than the OF-PC. The shoulder and IF-PC showed higher stress on laminate veneers, but lower stress on the cement layer. Ceramic veneers exhibited lower stress than composite resin veneers. CONCLUSIONS: The different incisal preparations for laminate veneers influenced stress distribution on restorations and on the resin cement layer. The shoulder type preparation showed better stress distribution and the composite resin veneers showed unfavorable results compared with the ceramic veneers.

2.
J Prosthet Dent ; 130(1): 19-27, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34756424

RESUMO

STATEMENT OF PROBLEM: Intraoral scanning has been reported to be preferred by patients over conventional impression making. Nevertheless, information regarding patient-related outcomes for conventional impression making and digital scanning is sparse. PURPOSE: The purpose of this systematic review and meta-analysis was to analyze patient-related outcomes of intraoral scanning and conventional impression methods. The primary outcomes evaluated were patient preference and satisfaction, and the secondary outcomes discomfort, nausea, unpleasant taste, breathing difficulty, pain, and anxiety. MATERIAL AND METHODS: Electronic and manual searches were performed for clinical trials that evaluated patient-related outcomes for intraoral scanning and conventional impression making for prosthetic rehabilitation. The Cochrane Collaboration risk of bias tool and Newcastle-Ottawa scale were used to assess the quality of the studies. Random-effects models using mean difference were used for meta-analyses. Heterogeneity was assessed using the Cochran Q test and I2 statistics (α=.05). RESULTS: The search strategy identified 1626 articles, and 11 studies were included in the meta-analyses. Patients preferred intraoral scanning to conventional impression making. The mean difference for patient preference was 15.02 (95% confidence interval of 8.33 - 21.73; P<.001). Discomfort, absence of nausea, absence of unpleasant taste, and absence of breathing difficulty were also significantly different (P<.05). CONCLUSIONS: Intraoral scanning is a suitable alternative to conventional impression procedures, promoting less discomfort for patients sensitive to taste, nausea, and breathing difficulty than when conventional impression making techniques are used.


Assuntos
Técnica de Moldagem Odontológica , Preferência do Paciente , Humanos , Desenho Assistido por Computador
3.
J Clin Exp Dent ; 10(6): e591-e597, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29930778

RESUMO

BACKGROUND: There is no ideal protocol for the surface treatment of fiber posts, especially when using a computer-aided design/computer-aided manufacturing (CAD/CAM) experimental fiberglass block. The purpose of this study was to evaluate the bond strength of a CAD/CAM customized glass fiber post and core after applying different surface treatment techniques. MATERIAL AND METHODS: Forty premolars were prepared to receive a customized CAD/CAM glass-fiber post and core obtained from an experimental block of glass fiber and epoxy resin. The specimens were randomly distributed in 4 groups (n=10) according to the post and core surface treatment: ETH - 70% ethanol; HP - 24% hydrogen peroxide for 1 minute; ETH/S - 70% ethanol + silane; HP/S - 24% hydrogen peroxide + silane. The universal adhesive containing silane was applied on the posts and prepared post spaces in all groups. The posts were cemented using dual cure resin cement. The specimens were stored in distilled water at 37°C for 24 h, cut (two slices of 1 mm for each root third - coronal, middle, and apical) and subjected to push-out test (0.5 mm/min). Data was subjected to two-way ANOVA (surface treatment and root third) and Tukey's test (α=0,05). RESULTS: There was no significant difference of bond strength values among groups, regardless the surface treatment (p >0.05). There was significant difference on bond strength values for the different root thirds (p<0.05) (coronal>middle=apical). CONCLUSIONS: The different surface treatment and application of additional silane in the CAD/CAM customized glass-fiber post and core does not interfere on bond strength values. The root dentin third interfered on the bond strength, with higher values for the coronal third. Key words:Post and core technique, cad/cam, shear strength, hydrogen peroxide.

4.
Compend Contin Educ Dent ; 39(3): e18-e21, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29493254

RESUMO

STATEMENT OF PROBLEM: Immediate placement and provisionalization of implants in fresh sockets has been previously demonstrated to be a predictable treatment in the restoration of non-recoverable teeth in the anterior regions of the maxilla. PURPOSE: This article reports a clinical case in which an immediate implant placement protocol was used in combination with two distinct and sequential grafts (bovine bone and connective tissue, respectively) followed by immediate implant provisionalization using the patient's crown of an extracted tooth. CLINICAL REPORT: Physical, clinical, and image examinations of the patient (female, 23 years old) revealed a maxillary central incisor (tooth No. 8) with slight mobility due the presence of extensive cervical resorption. The treatment proposed was the atraumatic extraction of the tooth followed by immediate implant placement and provisionalization. Two grafts (bovine bone and connective tissue) were used due to the presence of a very thin maxillary bone plate associated with a thin gingival biotype. RESULTS: The use of the extracted crown as a temporary crown after immediate implant placement resulted in immediate attainment of an esthetically pleasing outcome and long-term favorable results. CONCLUSION: The treatment protocol proposed can be efficiently used to immediately restore the patient's esthetics and function while maintaining the health, volume, and contours of gingival tissues over a 12-month follow-up period. CLINICAL IMPLICATIONS: Anterior teeth extractions typically require the execution of single-unit prostheses using dental materials of synthetic origin (such as polymers), which often are incapable of achieving the esthetic and physiological results patients expect. The use of the patient's own crown was demonstrated, which allowed good clinical results to be achieved and the natural shape and function of tissues to be maintained.


Assuntos
Coroas , Implantação Dentária Endóssea/métodos , Implantes Dentários para Um Único Dente , Restauração Dentária Temporária , Carga Imediata em Implante Dentário/métodos , Anormalidades Dentárias/cirurgia , Extração Dentária , Adulto , Animais , Bovinos , Estética Dentária , Feminino , Seguimentos , Humanos , Incisivo/anormalidades , Maxila/cirurgia , Coroa do Dente/anormalidades , Adulto Jovem
5.
Braz Dent J ; 28(1): 30-34, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28301010

RESUMO

Sonic vibrations may improve the bond strength and durability of fiberglass posts by improving adhesive penetration into dentin as well as the cement flow. The objective of this study was to evaluate the effect of sonic vibrations on the bond strength between fiberglass posts and root dentin using the pull-out test. Bovine roots were endodontically treated and divided randomly into four groups (n=12): Group C - conventional cementation (control); Group SA - sonic vibration (Smart Sonic Device, FGM) of the adhesive system and conventional post accommodation; SP group - conventional adhesive application and sonic vibration of the post during accommodation; and SASP - sonic vibration of the system adhesive and the post during accommodation. The posts were cleaned, treated with a silane and adhesive system (Ambar, FGM), and cemented with a dual-cured resin cement (Allcem Core, FGM). After 24 h, the specimens were subjected to mechanical tests and failure analyses. Representative specimens were analyzed by a scanning electron microscope to observe the cementation line. The results were analyzed using ANOVA and Tukey's test (a=5%). The bond strengths were as follows: SASP (90.9±27.1 N), C (121.4±60.6 N), SA (127.6±31.8 N) and SP (156.4±41.3 N). The use of sonic vibrations during the application of adhesive or post cementation separately did not affect the bond strength but had a negative effect when used for both procedures.


Assuntos
Dentina/química , Vidro , Técnica para Retentor Intrarradicular , Raiz Dentária/química , Vibração , Animais , Bovinos , Adesivos Dentinários/química , Técnicas In Vitro , Microscopia Eletrônica de Varredura
6.
Braz. dent. j ; 28(1): 30-34, Jan.-Feb. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-839118

RESUMO

Abstract Sonic vibrations may improve the bond strength and durability of fiberglass posts by improving adhesive penetration into dentin as well as the cement flow. The objective of this study was to evaluate the effect of sonic vibrations on the bond strength between fiberglass posts and root dentin using the pull-out test. Bovine roots were endodontically treated and divided randomly into four groups (n=12): Group C - conventional cementation (control); Group SA - sonic vibration (Smart Sonic Device, FGM) of the adhesive system and conventional post accommodation; SP group - conventional adhesive application and sonic vibration of the post during accommodation; and SASP - sonic vibration of the system adhesive and the post during accommodation. The posts were cleaned, treated with a silane and adhesive system (Ambar, FGM), and cemented with a dual-cured resin cement (Allcem Core, FGM). After 24 h, the specimens were subjected to mechanical tests and failure analyses. Representative specimens were analyzed by a scanning electron microscope to observe the cementation line. The results were analyzed using ANOVA and Tukey's test (a=5%). The bond strengths were as follows: SASP (90.9±27.1 N), C (121.4±60.6 N), SA (127.6±31.8 N) and SP (156.4±41.3 N). The use of sonic vibrations during the application of adhesive or post cementation separately did not affect the bond strength but had a negative effect when used for both procedures.


Resumo Vibrações sônicas podem melhorar a resistência e a durabilidade da união de pinos de fibra de vidro, melhorando a penetração do sistema adesivo à dentina, bem como o escoamento do cimento. O objetivo deste estudo foi avaliar o efeito da vibração sônica na resistência de união de pinos de fibra de vidro à dentina radicular, através de ensaio pull out. Raízes bovinas tratadas endodonticamente foram preparadas e divididas aleatoriamente em quatro grupos (n=12): Grupo C - cimentação convencional, (controle); Group SA - vibração sônica (Smart Sonic Device(r), FGM) do sistema adesivo e assentamento convencional do pino; grupo SP - aplicação convencional do sistema adesivo e vibração sônica no assentamento do pino; e SASP - vibração sônica do sistema adesivo e no assentamento do pino. Os retentores foram limpos, tratados com silano e sistema adesivo (Ambar, FGM) e cimentados com cimento resinoso dual (Allcem Core, FGM). Após 24 h as amostras foram submetidas ao teste mecânico e análise de falha. Amostras representativas foram avaliadas sob microscópio eletrônico de varredura, para avaliação da linha de cimentação. Os resultados foram analisados por meio de análise de variância e teste de Tukey (a=5%). Os resultados obtidos foram: SASP (90,9±27,1 N, C (121,4±60,6 N), SA (127,6±31,8 N) e SP (156,4±41,3 N). A vibração sônica para aplicação apenas do sistema adesivo ou pino não afetou a resistência de união, entretanto interferiu negativamente quando utilizada para ambos procedimentos.


Assuntos
Animais , Bovinos , Dentina/química , Vidro , Técnica para Retentor Intrarradicular , Raiz Dentária/química , Vibração , Adesivos Dentinários/química , Técnicas In Vitro , Microscopia Eletrônica de Varredura
7.
Dent Mater ; 33(2): 144-151, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27890357

RESUMO

OBJECTIVE: To evaluate the stress distribution in bi-layered Y-TZP based crowns, according to the occlusal internal spacing between coping and abutment. METHODS: Twelve premolar shaped Y-TZP copings were made by a CAD/CAM system and seated on an abutment to evaluate the internal fit at the occlusal third using micro-CT images. Considering the fitting range obtained experimentally, two 3D finite element models, consisting on bone tissue, a titanium implant, a zirconia abutment, cement layer and a bi-layered Y-TZP ceramic crown were constructed based on the micro-CT images, one corresponding to the thinnest cement space and other representing the specimen with the thickest cement space obtained experimentally. A 250N axial load was applied at the center of the occlusal surface of the crown (≅0,8mm2 area) and the first principal stress distribution was plotted and analyzed. RESULTS: The greatest maximum principal stress occurred within the veneer ceramic right below the site of loading. The thickest cement model showed higher stress concentration at the center of occlusal surface of veneer and the center of occlusal internal surface of coping. SIGNIFICANCE: Knowledge of stress distribution in ceramic crowns with different cement thicknesses will help clinicians to properly adjust crown fit, in seeking to avoid porcelain fractures.


Assuntos
Coroas , Planejamento de Prótese Dentária , Análise do Estresse Dentário , Ítrio , Zircônio , Porcelana Dentária , Análise de Elementos Finitos , Humanos , Estresse Mecânico
8.
J Craniofac Surg ; 26(7): 2196-200, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26192032

RESUMO

This study aimed to analyze the stress distribution in single implant system and to evaluate the compatibility of an in vitro model with finite element (FE) model. The in vitro model consisted of Brånemark implant; multiunit set abutment of 5 mm height; metal-ceramic screw-retained crown, and polyurethane simulating the bone. Deformations were recorded in the peri-implant region in the mesial and distal aspects, after an axial 300 N load application at the center of the occlusal aspect of the crown, using strain gauges. This in vitro model was scanned with micro CT to design a three-dimensional FE model and the strains in the peri-implant bone region were registered to check the compatibility between both models. The FE model was used to evaluate stress distribution in different parts of the system. The values obtained from the in vitro model (20-587 µÎµ) and the finite element analysis (81-588 µÎµ) showed agreement among them. The highest stresses because of axial and oblique load, respectively were 5.83 and 40 MPa for the cortical bone, 55 and 1200 MPa for the implant, and 80 and 470 MPa for the abutment screw. The FE method proved to be effective for evaluating the deformation around single implant. Oblique loads lead to higher stress concentrations.


Assuntos
Implantes Dentários para Um Único Dente , Análise de Elementos Finitos , Imageamento Tridimensional/métodos , Silicatos de Alumínio/química , Fenômenos Biomecânicos , Ligas de Cromo/química , Simulação por Computador , Coroas , Projeto do Implante Dentário-Pivô , Porcelana Dentária/química , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário/instrumentação , Humanos , Mandíbula/fisiologia , Teste de Materiais , Ligas Metalo-Cerâmicas/química , Modelos Anatômicos , Modelos Biológicos , Compostos de Potássio/química , Estresse Mecânico , Microtomografia por Raio-X/métodos
9.
Bauru; s.n; 2015. 113 p. ilus, tab, graf.
Tese em Português | LILACS | ID: lil-794217

RESUMO

A longevidade das coroas cerâmicas depende, entre outros fatores, de sua adaptação ao pilar, bem como da distribuição das tensões nas mesmas. Não há um consenso sobre a melhor adaptação dos copings de zircônia feitos em CAD/CAM em relação aos métodos convencionais, podendo haver uma influência da contração de sinterização sobre esta. O presente estudo avaliou as alterações dimensionais decorrentes do processo de sinterização em três diferentes marcas comerciais de blocos de zircônia, relacionando-as com a adaptação de copings confeccionados por um sistema CAD/CAM, além de avaliar como a adaptação de tais copings poderia impactar na distribuição de tensões em coroas cerâmicas bi-camadas com estrutura de zircônia. A contração de sinterização das três marcas comerciais de zircônia foi obtida experimentalmente a partir da mensuração de espécimes geométricos. Trinta e seis copings de zircônia confeccionados por CAD/CAM foram divididos em três grupos (n=12): ZMAX a partir de blocos de IPS E.max ZirCad (Ivoclar Vivadent; Liechtenstein); ZYZ blocos de InCeram YZ (Vita Zahnfabrik; Alemanha) e; ZMC zircônia de manufatura controlada (Zirklein/Biodinâmica; Brasil). Os copings foram escaneados em micro-CT antes a após a sinterização para que as alterações dimensionais decorrentes do processo de sinterização fossem obtidas a partir da mensuração de cortes específicos. Os dados das alterações dimensionais obtidos para os espécimes geométricos e para os copings foram confrontados com as taxas de contração de sinterização informadas pelos fabricantes dos blocos de zircônia. Os copings sinterizados foram assentados sobre um pilar de zircônia e levados ao micro-CT para averiguação da adaptação interna e marginal dos mesmos. As mensurações foram realizadas pelo software ImageJ em 33 pontos diferentes. Os dados da adaptação possibilitaram a comparação estatística (p0,05) entre marcas comerciais e locais de mensuração, bem como a comparação entre a adaptação...


The longevity of ceramic crowns depends, among other factors, on its fit and the stress distribution. There is no consensus regarding the better fitting of zirconia CAD/CAM made crowns over conventional methods and may be an influence of zirconia sintering shrinkage on the abutment/coping spacing. This study aimed at evaluating the dimensional changes from sintering process of three zirconia blocks trademarks, relating them to the fit of CAD / CAM made zirconia copings, and to evaluate how the fit of such copings could impact on the stress distribution in bilayered Y-TZP based ceramic crowns. The sintering shrinkage of the three trademarks of zirconia was obtained experimentally from the measurement of geometric specimens. Thirty-six zirconia copings made by CAD / CAM were equally divided into three groups (n = 12): ZMAX - from blocks of IPS e.max ZirCAD (Ivoclar Vivadent, Liechtenstein); ZYZ - InCeram YZ blocks (Vita Zahnfabrik, Germany) and; ZMC - controlled manufacturing zirconia (Zirklein/Biodinamica, Brazil). The copings were scanned in micro-CT before and after the sintering so that dimensional changes from the sintering process were obtained from measurements taken from specific slices. Data from dimensional changes obtained for the geometric specimens and for the copings were faced with the sintering shrinkage rates reported by the manufacturers of zirconia blanks. The sintered copings were settled on a zirconia abutment and taken to the micro-CT scanner to evaluate its marginal and internal fit. Thirty three different points were measured using the Image J software. The data enabled the statistical comparison (p 0,05) between trademarks and measurement sites, as well as the comparison between the fit obtained experimentally with that stipulated by the CAD / CAM software. The micro-CT images of copings with smaller and larger cement space were used to build finite element models to evaluate stress distribution as a function of the abutment...


Assuntos
Humanos , Desenho Assistido por Computador , Coroas , Cerâmica/química , Planejamento de Prótese Dentária/métodos , Zircônio/química , Análise de Variância , Adaptação Marginal Dentária , Temperatura Alta , Teste de Materiais , Valores de Referência , Resistência à Tração , Tomografia Computadorizada por Raios X
10.
Bauru; s.n; 2015. 113 p. ilus, tab, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-867423

RESUMO

A longevidade das coroas cerâmicas depende, entre outros fatores, de sua adaptação ao pilar, bem como da distribuição das tensões nas mesmas. Não há um consenso sobre a melhor adaptação dos copings de zircônia feitos em CAD/CAM em relação aos métodos convencionais, podendo haver uma influência da contração de sinterização sobre esta. O presente estudo avaliou as alterações dimensionais decorrentes do processo de sinterização em três diferentes marcas comerciais de blocos de zircônia, relacionando-as com a adaptação de copings confeccionados por um sistema CAD/CAM, além de avaliar como a adaptação de tais copings poderia impactar na distribuição de tensões em coroas cerâmicas bi-camadas com estrutura de zircônia. A contração de sinterização das três marcas comerciais de zircônia foi obtida experimentalmente a partir da mensuração de espécimes geométricos. Trinta e seis copings de zircônia confeccionados por CAD/CAM foram divididos em três grupos (n=12): ZMAX a partir de blocos de IPS E.max ZirCad (Ivoclar Vivadent; Liechtenstein); ZYZ blocos de InCeram YZ (Vita Zahnfabrik; Alemanha) e; ZMC zircônia de manufatura controlada (Zirklein/Biodinâmica; Brasil). Os copings foram escaneados em micro-CT antes a após a sinterização para que as alterações dimensionais decorrentes do processo de sinterização fossem obtidas a partir da mensuração de cortes específicos. Os dados das alterações dimensionais obtidos para os espécimes geométricos e para os copings foram confrontados com as taxas de contração de sinterização informadas pelos fabricantes dos blocos de zircônia. Os copings sinterizados foram assentados sobre um pilar de zircônia e levados ao micro-CT para averiguação da adaptação interna e marginal dos mesmos. As mensurações foram realizadas pelo software ImageJ em 33 pontos diferentes. Os dados da adaptação possibilitaram a comparação estatística (p0,05) entre marcas comerciais e locais de mensuração, bem como a comparação entre a adaptação...


The longevity of ceramic crowns depends, among other factors, on its fit and the stress distribution. There is no consensus regarding the better fitting of zirconia CAD/CAM made crowns over conventional methods and may be an influence of zirconia sintering shrinkage on the abutment/coping spacing. This study aimed at evaluating the dimensional changes from sintering process of three zirconia blocks trademarks, relating them to the fit of CAD / CAM made zirconia copings, and to evaluate how the fit of such copings could impact on the stress distribution in bilayered Y-TZP based ceramic crowns. The sintering shrinkage of the three trademarks of zirconia was obtained experimentally from the measurement of geometric specimens. Thirty-six zirconia copings made by CAD / CAM were equally divided into three groups (n = 12): ZMAX - from blocks of IPS e.max ZirCAD (Ivoclar Vivadent, Liechtenstein); ZYZ - InCeram YZ blocks (Vita Zahnfabrik, Germany) and; ZMC - controlled manufacturing zirconia (Zirklein/Biodinamica, Brazil). The copings were scanned in micro-CT before and after the sintering so that dimensional changes from the sintering process were obtained from measurements taken from specific slices. Data from dimensional changes obtained for the geometric specimens and for the copings were faced with the sintering shrinkage rates reported by the manufacturers of zirconia blanks. The sintered copings were settled on a zirconia abutment and taken to the micro-CT scanner to evaluate its marginal and internal fit. Thirty three different points were measured using the Image J software. The data enabled the statistical comparison (p 0,05) between trademarks and measurement sites, as well as the comparison between the fit obtained experimentally with that stipulated by the CAD / CAM software. The micro-CT images of copings with smaller and larger cement space were used to build finite element models to evaluate stress distribution as a function of the abutment...


Assuntos
Desenho Assistido por Computador , Coroas , Cerâmica/química , Planejamento de Prótese Dentária/métodos , Zircônio/química , Análise de Variância , Adaptação Marginal Dentária , Temperatura Alta , Teste de Materiais , Valores de Referência , Resistência à Tração , Tomografia Computadorizada por Raios X
11.
J Appl Oral Sci ; 22(3): 209-17, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25025562

RESUMO

UNLABELLED: Knowing how stresses are dissipated on the fixed implant-supported complex allows adequate treatment planning and better choice of the materials used for prosthesis fabrication. OBJECTIVES: The aim of this study was to evaluate the deformation suffered by cantilevered implant-supported fixed prostheses frameworks cast in silver-palladium alloy and coated with two occlusal veneering materials: acrylic resin or porcelain. MATERIAL AND METHODS: Two strain gauges were bonded to the inferior surface of the silver-palladium framework and two other were bonded to the occlusal surface of the prosthesis framework covered with ceramic and acrylic resin on each of its two halves. The framework was fixed to a metallic master model and a 35.2 N compression force was applied to the cantilever at 10, 15 and 20 mm from the most distal implant. The measurements of deformation by compression and tension were obtained. The statistical 2-way ANOVA test was used for individual analysis of the experiment variables and the Tukey test was used for the interrelation between all the variables (material and distance of force application). RESULTS: The results showed that both variables had influence on the studied factors (deformation by compression and tension). CONCLUSION: The ceramic coating provided greater rigidity to the assembly and therefore less distortion compared with the uncoated framework and with the resin-coated framework. The cantilever arm length also influenced the prosthesis rigidity, causing higher deformation the farther the load was applied from the last implant.


Assuntos
Resinas Acrílicas/química , Ligas Dentárias/química , Porcelana Dentária/química , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Facetas Dentárias , Análise de Variância , Força Compressiva , Técnica de Fundição Odontológica , Análise do Estresse Dentário , Teste de Materiais , Paládio/química , Valores de Referência , Reprodutibilidade dos Testes , Prata/química , Propriedades de Superfície , Resistência à Tração , Fatores de Tempo
12.
J. appl. oral sci ; 22(3): 209-217, May-Jun/2014. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-711709

RESUMO

Knowing how stresses are dissipated on the fixed implant-supported complex allows adequate treatment planning and better choice of the materials used for prosthesis fabrication. Objectives: The aim of this study was to evaluate the deformation suffered by cantilevered implant-supported fixed prostheses frameworks cast in silver-palladium alloy and coated with two occlusal veneering materials: acrylic resin or porcelain. Material and Methods: Two strain gauges were bonded to the inferior surface of the silver-palladium framework and two other were bonded to the occlusal surface of the prosthesis framework covered with ceramic and acrylic resin on each of its two halves. The framework was fixed to a metallic master model and a 35.2 N compression force was applied to the cantilever at 10, 15 and 20 mm from the most distal implant. The measurements of deformation by compression and tension were obtained. The statistical 2-way ANOVA test was used for individual analysis of the experiment variables and the Tukey test was used for the interrelation between all the variables (material and distance of force application). Results: The results showed that both variables had influence on the studied factors (deformation by compression and tension). Conclusion: The ceramic coating provided greater rigidity to the assembly and therefore less distortion compared with the uncoated framework and with the resin-coated framework. The cantilever arm length also influenced the prosthesis rigidity, causing higher deformation the farther the load was applied from the last implant. .


Assuntos
Resinas Acrílicas/química , Ligas Dentárias/química , Porcelana Dentária/química , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Facetas Dentárias , Análise de Variância , Força Compressiva , Técnica de Fundição Odontológica , Análise do Estresse Dentário , Teste de Materiais , Paládio/química , Valores de Referência , Reprodutibilidade dos Testes , Prata/química , Propriedades de Superfície , Resistência à Tração , Fatores de Tempo
13.
Rev. odontol. UNESP (Online) ; 42(3): 196-203, maio-jun. 2013. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-678423

RESUMO

Introdução: A estabilidade dimensional das resinas acrílicas influencia na adaptação das coroas provisórias e, consequentemente, no resultado do tratamento reabilitador. Objetivo: Avaliar a estabilidade dimensional, ao longo do tempo, de uma resina acrílica processada de diferentes maneiras. Material e Método: Cinco técnicas de polimerização da resina acrílica foram testadas: I - polimerização térmica utilizando líquido de polimerização rápida em mufla; II - autopolimerização sob pressão; III - autopolimerização utilizando pincel; IV - autopolimerização após mistura (pó + líquido) em pote Dappen e inserção em matriz de aço na fase arenosa; V - autopolimerização após mistura em pote Dappen com inserção na matriz metálica na fase plástica. Foram confeccionados dez corpos de prova para cada tipo de processamento. Avaliou-se a estabilidade dimensional por meio de matriz de aço inox confeccionada segundo a especificação nº19 da ADA. Os corpos de prova foram armazenados em água destilada a 37ºC e examinados nos períodos de 1 hora, 1, 7, 15, 10, 90 e 180 dias após a polimerização, com o auxílio de um microscópio óptico com aumento de 20×. Os resultados foram submetidos à análise de dupla variância (Teste de Tukey para Tempo e Técnica de processamento) em nível de 5% de significância. Resultado: Todos os grupos experimentais apresentaram alterações dimensionais entre o sétimo e o 15º dia; após esse período de tempo, houve alterações dimensionais estatisticamente significantes, para as diferentes técnicas estudadas. Conclusão: A estabilidade dimensional da resina acrílica não sofreu influência das diferentes técnicas de processamento avaliadas; entretanto, foi influenciada pelo tempo de armazenamento.


Introduction: The dimensional stability of acrylic resins influences the temporary crowns fitting and can affect the final restoration results. Objective: To evaluate the long-term dimensional stability of an acrylic resin used for fabrication of provisional crowns. Material and Method: Five types of processing techniques were evaluated: I - thermal polymerization using fast polymerization liquid and flask; II - auto-polimerization under pressure in a stainless steel matrix; III - auto-polimerization using the bead brush technique to build the sample; IV - auto-polimerization after mixture (powder + liquid) in a dappen dish and insertion in a stainless steel matrix at the sand stage; V - auto-polimerization after mixture in a dappen dish with insertion in a stainless steel matrix at the plastic stage. For each type of processing technique, 10 samples were made. Dimensional stability was evaluated by means of a steel matrix made following the ADA specification nº19. The samples were stored in distilled water at 37 ºC and examined at the periods of 1 hour, 1, 7, 15, 30, 90 and 180 days, with an optic microscope with 20× magnification. The results were subjected to the 2-way analysis of variance (Tukey Test) at the significance level of 5% for the variables Time and Processing Technique. Result: All samples had dimensional alterations from day 7 to the day 15, regardless of the technique used. From day 15 to 180, there were no statistically significant dimensional alterations. Conclusion: The dimensional stability of the acrylic resin was not influenced by the different processing techniques tested, however, it was influenced by the storage time.


Assuntos
Resinas Acrílicas , Adaptação Marginal Dentária , Polimetil Metacrilato , Coroas , Restauração Dentária Temporária , Prótese Parcial Fixa , Análise de Variância , Interpretação Estatística de Dados , Microscopia
14.
Braz. dent. sci ; 16(2): 44-50, 2013. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-698289

RESUMO

Objective: This study aimed at evaluating the micro-hardness of an acrylic resin used for provisional crowns. Materials and methods: Five different processing techniques (direct and indirect) were assessed: (I) auto polymerizing resin in sandy stage; (II) auto polymerizing resin in plastic stage; (III) bead-brush technique; (IV) auto polymerizing resin under pressure; (V) heatcured acrylic resin under pressure. Five specimens were made for each test group. For the initial micro-hardness test, the specimens were immersed in deionized water for 48 hours. For the analysis of the final micro-hardness, the specimens were subjected to pH-cycling to simulate the changes in the pH level which occur in the oral cavity. Results: Tests revealed that the micro-hardness was decreased after the pH-cycling. However, no statistical difference was found among the different types of acrylic resin polymerization techniques. Conclusion: It was concluded that the micro-hardness is not directly related to the polymerization technique for making provisional


Objetivo: Avaliou-se a dureza superficial de uma resina acrílica (PMMA) utilizada para a confecção de coroas provisórias. Material e Métodos: Cinco diferentes técnicas de processamento (Direta e Indireta) para polimerização da resina foram testadas: I - autopolimerização após mistura (pó + líquido) em pote dappen e inserção em matriz de silicona na fase arenosa; II - autopolimerização após mistura em pote dappen com inserção em matriz de silicona na fase plástica; III - autopolimerização utilizando a técnica do pincel; IV - autopolimerização sob pressão em matriz de silicona; V - polimerização térmica utilizando líquido de polimerização rápida em mufla. Foram confeccionados cinco corpos-de-prova para cada grupo. Para o teste de microdureza inicial os espécimes foram imersos em água deionizada por 48 horas. Para a análise da dureza final, os espécimes foram submetidos a ciclos dinâmicos de pH, para simular a variação de pH ocorrida na cavidade oral. Resultados: Os testes revelaram que houve diminuição da dureza do material após a ciclagem ácida, porém não foi verificada diferença estatística entre os diferentes tipos de processamento da resina acrílica. Conclusão: Concluiu-se que a microdureza não está relacionada diretamente com a técnica de confecção dos provisórios.


Assuntos
Resinas Acrílicas , Coroas , Prótese Dentária , Prótese Parcial Temporária
15.
RGO (Porto Alegre) ; 58(2): 239-242, abr.-jun. 2010.
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-874111

RESUMO

Diversos estudos têm mostrado altas frequências de sucesso na reabilitação oral por meio de implantes dentários. Entretanto, podem ocorrer fracassos por complicações logo após a sua instalação ou, posteriormente, quando a prótese sobre o implante já está em função há algum tempo. As falhas tardias podem ocorrer em situações nas quais a osseointegração de um implante previamente estável e em função é perdida por sobrecarga e/ou infecção, sendo que, um dos fatores de infecção é a infiltração de bactérias através de falhas existentes na conexão implante/pilar. Com essas considerações, o objetivo deste trabalho foi, de por meio de uma revisão de literatura discorrer sobre a infiltração de fluídos e bactérias no interior dos implantes, que ocorre devido à falha na conexão implante/pilar protético. Concluiu-se que mesmo com o desenvolvimento de novos implantes e pilares e a tentativa de alguns autores de buscarem o vedamento dessa microfissura a infiltração bacteriana entre implante/pilar não foi evitada.


Many studies have shown high rates of successful oral rehabilitation with implants. However, complications may occur immediately after the implant is placed or some time later, when the prosthesis has already been used for some time. These complications may lead to implant failure. Late failures can happen in situations where the osseointegration of a previously stable and functional implant is lost because of an overload and/or an infection. One of the causes of infection is the infiltration of bacteria in failures present in the implant-abutment interface. With this in mind, the purpose of this study was to address the infiltration of liquids and bacteria inside the implant due to failures in the implant-abutment interface based on a literature review. In conclusion, despite the development of new implants and abutments and the attempts of some authors to seal microfissures, bacterial infiltration in the implant-abutment interface still occurred.


Assuntos
Doenças Periodontais , Implantes Dentários , Infecções Bacterianas , Infiltração Dentária/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...